Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 297

Advertising
background image

9 Troubleshooting

9-32

Position Error

(Without Alarm)

(cont’d)

Noise interference due to length of
I/O signal cable

Check the I/O signal cable length.

The I/O signal cable length must be
less than 3 m.

An encoder fault occurred. (The
pulse count does not change.)

Replace the servomotor.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

Servomotor

Overheated

Ambient temperature too high

Measure the servomotor ambient

temperature.

Lower the ambient temperature to

40

°C or less.

Servomotor surface dirty

Visually check the surface.

Clean dust and oil from the surface.

Servomotor overloaded

Check the load status with monitor.

If overloaded, reduce load or
replace with larger capacity servo-
motor.

(cont’d)

Problem

Probable Cause

Investigative Actions

Corrective Actions