3 application example of safety functions, 1) connection example, 2) failure detection method – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 134

Advertising
background image

4.6 Safety Function

4-51

Operation

4.6.3 Application Example of Safety Functions

An example of using safety functions is shown below.

(1) Connection Example

In the following example, a safety unit is used and the HWBB function operates when the guard opens.

When a guard opens, both of signals, the /HWBB1 and the /HWBB2, turn OFF, and the EDM1 signal is ON.

Since the feedback is ON when the guard closes, the safety unit is reset, and the /HWBB1 and the /HWBB2
signals turn ON, and the operation becomes possible.

Note: Connect the EDM1 as the direction of current flows from EMD1+ to EMD1-, because the EMD1 has polarity with a

transistor output.

(2) Failure Detection Method

In case of a failure such as the /HWBB1 or the /HWBB2 signal remains ON, the safety unit is not reset
because the EDM1 signal keeps OFF. Therefore starting is impossible, then the failure is detected.

An error in the external device, disconnection or short-circuiting of the external wiring, or a failure in the
SERVOPACK must be considered. Find the cause and correct the problem.

/HWBB1

+

4

3

6

5

8

7

A1

A2

T11 T12 T21

T31 T32 T33

S24 S14

T22

/HWBB1

/HWBB2

+

/HWBB2

EDM1

+

EDM1

0 V

CN8

SERVOPACK

Output

24 V

Power
supply

Guard

Safety unit

manufactured

by OMRON Corp.

G9SX-BC202

Fuse

Close

Limit switch

Power
supply

input

Input

Reset/feedback
input

Open