5.8 Additional Adjustment Function
5-55
Adjustments
(5) Parameters for Automatic Gain Switching
(6) Related Monitor
Note: When using the tuning-less function, gain setting 1 is enabled.
Pn131
Gain Switching Time 1
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 65535
1 ms
0
Immediately
Tuning
Pn132
Gain Switching Time 2
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 65535
1 ms
0
Immediately
Tuning
Pn135
Gain Switching Waiting Time 1
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 65535
1 ms
0
Immediately
Tuning
Pn136
Gain Switching Waiting Time 2
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 65535
1 ms
0
Immediately
Tuning
Monitor No. (Un)
Name
Value
Remarks
Un014
Effective gain monitor
1
For gain setting 1
2
For gain setting 2
Position
Position
Position
Position
Parameter
Analog Monitor
Name
Output Value
Remarks
Pn006
Pn007
n.
0B
Active gain
1 V
Gain setting 1 is enabled.
2 V
Gain setting 2 is enabled.