5.8 Additional Adjustment Function

5-55

Adjustments

(5) Parameters for Automatic Gain Switching

(6) Related Monitor

Note: When using the tuning-less function, gain setting 1 is enabled.

Pn131

Gain Switching Time 1

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 65535

1 ms

0

Immediately

Tuning

Pn132

Gain Switching Time 2

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 65535

1 ms

0

Immediately

Tuning

Pn135

Gain Switching Waiting Time 1

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 65535

1 ms

0

Immediately

Tuning

Pn136

Gain Switching Waiting Time 2

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 65535

1 ms

0

Immediately

Tuning

Monitor No. (Un)

Name

Value

Remarks

Un014

Effective gain monitor

1

For gain setting 1

2

For gain setting 2

Position

Position

Position

Position

Parameter

Analog Monitor

Name

Output Value

Remarks

Pn006
Pn007

n.

0B

Active gain

1 V

Gain setting 1 is enabled.

2 V

Gain setting 2 is enabled.