3.8 Noise Control and Measures for Harmonic Suppression

3-39

Wiring and Connection

3.8.3 Connecting AC/DC Reactor for Harmonic Suppression

The SERVOPACK has reactor connection terminals for power supply harmonic suppression.

As for the precautions on selecting an AC or DC reactor and its specifications, refer to

Σ

-V series Product Cat-

alog (KAEP S800000 42).
Connect a reactor as shown in the following diagram.

Note 1. Connection terminals for DC reactor

1 and 2 are short-circuited at shipment. Remove the lead wire for

short-circuit, and connect a DC reactor.

2. AC and DC reactors are not provided. (option)
3. A SERVOPACK with a single-phase, 100-V power supply input cannot be connected to a DC reactor.

SERVOPACK AC Reactor with

100-VAC Power Supply Input

SERVOPACK DC Reactor with

200/400-VAC Power Supply Input

L1

L2

SERVOPACK

AC reactor

Power
supply

1

2

SERVOPACK

DC reactor

Advertising