5 Adjustments

5.4.2 Advanced Autotuning by Reference Procedure

5-28

(3) Related Functions

Notch Filter

Usually, set this function to Auto Setting. (The notch filter is factory-set to Auto Setting.)

If this function is set to Auto Setting, vibration will be detected automatically and the notch filter will be set.

Set this function to Not Auto Setting only if you do not change the notch filter setting before executing
advanced autotuning by reference.

Anti-Resonance Control Adjustment Function

This function reduces low vibration frequency; which the notch filter does not detect.

Usually, set this function to Auto Setting. (The anti-resonance control is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning

by reference and anti-resonance control will be automatically adjusted and set.

Vibration Suppression

The vibration suppression function suppresses transitional vibration at frequency as low as 1 to 100 Hz that is

generated mainly when positioning if the machine stand vibrates.

Usually, set this function to Auto Setting. (The vibration suppression function is factory-set to Auto Setting.)
When this function is set to Auto Setting, vibration will be automatically detected during advanced autotuning

by reference and model following control with vibration suppression will be automatically adjusted and set.
Set this function to Not Auto Setting only if you do not change the setting for model following control with

vibration suppression before executing advanced autotuning by reference.

Note: This function uses model following control. Therefore, the function can be executed only if the mode is set to 2 or 3.

Related Parameters

Parameter

Function

When Enabled

Classification

Pn460

n.

0

Does not set the 1st notch filter automatically.

Immediately

Tuning

n.

1

Sets the 1st notch filter automatically.
[Factory setting]

n. 0

Does not set the 2nd notch filter automatically.

n. 1

Sets the 2nd notch filter automatically.
[Factory setting]

Parameter

Function

When Enabled

Classification

Pn160

n.

0

Does not use the anti-resonance control automati-

cally.

After restart

Tuning

n.

1

Uses the anti-resonance control automatically.
[Factory setting]

Parameter

Function

When Enabled

Classification

Pn140

n. 0

Does not use the vibration suppression function auto-
matically.

Immediately

Tuning

n. 1

Uses the vibration suppression function automati-
cally. [Factory setting]