5 Adjustments

5.8.3 Current Control Mode Selection

5-58

5.8.3 Current Control Mode Selection

This function reduces high-frequency noises while the motor is being stopped. This function is enabled by

default and set to be effective under different application conditions.

5.8.4 Current Gain Level Setting

This function reduces noises by adjusting the parameter value for current control inside the SERVOPACK

according to the speed loop gain (Pn100). The noise level can be reduced by reducing the current gain level
(Pn13D) from its factory setting of 2000% (disabled). If the set value of Pn13D is decreased, the level of noise

will be lowered, but the response characteristics of the SERVOPACK will also be degraded. Adjust the current

gain level within the allowable range at which SERVOPACK response characteristics can be secured.

5.8.5 Speed Detection Method Selection

This function can ensure smooth movement of the motor while the motor is running. This function is disabled

by default. Set the value of Pn009.2 = 1 to enable this function.

Input Voltage

Applicable SERVOPACK Model SGDV-

200 V

120A

A, 180A

A, 200A

A, 330A

A,

470A

A, 550A

A, 590A

A, 780A

A

400 V

3R5D

A, 5R4D

A, 8R4D

A, 120D

A,

170D

A, 210D

A, 260D

A, 280D

A,

370D

A

Parameter

Meaning

When Enabled

Classification

Pn009

n.

0

Selects the current control mode 1.
(Does not perform the switching.)

After restart

Tuning

n.

1

Selects the current control mode 2.
(Performs the switching.) [Factory setting]

• When this function is executed, the load ratio may increase while the servomotor is

being stopped.

Pn13D

Current Gain Level

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

100 to 2000

1 %

2000

Immediately

Tuning

• If the parameter setting of the current gain level is changed, the responsiveness char-

acteristic of the speed loop will also change. The servo must, therefore, be readjusted
again.

Speed

Position

Parameter

Meaning

When Enabled

Classification

Pn009

n. 0

Selects speed detection 1. [Factory setting]

After restart

Tuning

n. 1

Selects speed detection 2.

• If this function is changed, the responsiveness characteristic of the speed loop will

also change. The servo must, therefore, be readjusted again.