2 i/o signal connections, 1 i/o signal (cn1) names and functions, 1) input signals – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 63

Advertising
background image

3.2 I/O Signal Connections

3-19

Wiring and Connection

3.2 I/O Signal Connections

This section describes the names and functions of I/O signals (CN1). Also, connection examples by control

method are shown.

3.2.1 I/O Signal (CN1) Names and Functions

The following table shows the names and functions of I/O signals (CN1).

(1) Input Signals

Note 1. The functions allocated to /SI3, P-OT, N-OT, /SI4, /SI5, and /SI6 input signals can be changed by using the

parameters. Refer to 3.3.1 Input Signal Allocations.

2. If the Forward run prohibited/Reverse run prohibited function is used, the software can be used to stop the SER-

VOPACK. If the application does not satisfy the safety requirements, add an external circuit for safety reasons as
required.

Regarding the allocation and use of I/O signals, they differ in accordance with the con-
nected option module. For details, refer to the manual for the command option module
that is connected.

Signal

Pin No.

Name

Function

Refer-

ence

Section

/SI3

9

Command option
module input 3

Connects the external input signal used in the command
option module.

P-OT

7

Forward run
prohibited

Overtravel prohibited: Stops servomotor when movable part
travels beyond the allowable range of motion.

4.2.2

N-OT

8

Reverse run
prohibited

/SI4

10

Command option
module input 4

Connects the external input signal used in the command

option module.

/SI5

11

Command option
module input 5

/SI6

12

Command option
module input 6

+24VIN

6

Control power sup-
ply input for
sequence signal

Control power supply input for sequence signals.
Allowable voltage fluctuation range: 11 to 25 V
Note: The

+24-V power supply is not included.

3.4.1

BAT(+)

14

Battery (

+) input

Connecting pin for the absolute encoder backup battery.

BAT(-)

15

Battery (

−) input

/SI0

13

General-purpose
input

Connects the external input signal used in the command
option module.

Advertising