3.7 Regenerative Resistors Connections

3-33

Wiring and Connection

(3) SERVOPACKs: Model SGDV-470A, 550A, 590A, 780A, 210D, 260D, 280D, 370D

No built-in regenerative resistor is provided, so an external regenerative resistor unit is required. The regener-

ative resistor units are as follows:

Connect a regenerative resistor unit between the B1 and B2 terminals.

When using a regenerative resistor unit, use the factory setting for Pn600. If a non-Yaskawa regenerative resis-

tor is used, make the setting for Pn600.

Main Circuit

Power Supply

SERVOPACK Model

SGDV-

Applicable

Regenerative

Resistor Unit

Resistance

(

Ω)

Specifications

Three-phase
200 V

470A

JUSP-RA04-E

6.25

25

Ω (220 W); 4 resistors in parallel

550A, 590A, 780A

JUSP-RA05-E

3.13

25

Ω (220 W); 8 resistors in parallel

Three-phase
400 V

210D, 260D

JUSP-RA18-E

18

18

Ω (220 W); 2 resistors in series with 2 in

parallel.

280D, 370D

JUSP-RA19-E

14.25

28.5

Ω (220 W); 2 resistors in series with 4 in

parallel.

Regenerative Resistor Unit

JUSP-RA

-E

SERVOPACK