Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual
Page 77

3.7 Regenerative Resistors Connections
3-33
Wiring and Connection
(3) SERVOPACKs: Model SGDV-470A, 550A, 590A, 780A, 210D, 260D, 280D, 370D
No built-in regenerative resistor is provided, so an external regenerative resistor unit is required. The regener-
ative resistor units are as follows:
Connect a regenerative resistor unit between the B1 and B2 terminals.
When using a regenerative resistor unit, use the factory setting for Pn600. If a non-Yaskawa regenerative resis-
tor is used, make the setting for Pn600.
Main Circuit
Power Supply
SERVOPACK Model
SGDV-
Applicable
Regenerative
Resistor Unit
Resistance
(
Ω)
Specifications
Three-phase
200 V
470A
JUSP-RA04-E
6.25
25
Ω (220 W); 4 resistors in parallel
550A, 590A, 780A
JUSP-RA05-E
3.13
25
Ω (220 W); 8 resistors in parallel
Three-phase
400 V
210D, 260D
JUSP-RA18-E
18
18
Ω (220 W); 2 resistors in series with 2 in
parallel.
280D, 370D
JUSP-RA19-E
14.25
28.5
Ω (220 W); 2 resistors in series with 4 in
parallel.
Regenerative Resistor Unit
JUSP-RA
-E
SERVOPACK