1) operating procedure – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 235

Advertising
background image

6.21 EasyFFT (Fn206)

6-33

Utility Functions (Fn

)

(1) Operating Procedure

Follow the steps below.

• Starts EasyFFT when the servomotor power is OFF.
• Do not input the reference from outside because EasyFFT outputs the special

reference from the SERVOPACK.

Start

When using mainly for servo gain adjustment, etc.

End

Vibration with

high-frequency noise

during operation

Turn OFF the servo, and
execute EasyFFT (Fn206).

No

No

Yes

Yes

Adjust servo gain.

Vibration

With the servo ON, execute
Online Vibration Monitor
(Fn207).

Step

Display Example

Keys

Description

1

Press the

Key to open the Utility Function Mode

main menu and select Fn206.

2

Press the

Key. The display is switched to the

execution display of Fn206.
Note: If the display is not switched and “NO-OP” is

displayed in the status display, change the fol-
lowing settings. (Refer to 6.12.)

•If Write Prohibit is set in Fn010:

→ Cancel the Write Prohibited setting.

•If a servo ON command is input:

→ Send a servo OFF command.