Basic specifications of SERVOPACKs are shown below.

Control Method

IGBT-PWM (sine-wave driven)

Feedback

Serial encoder:
13-bit (incremental), 17-bit, 20-bit (incremental/absolute)

Operating

Conditions

Surrounding Air/Storage

Temperature

0 to +55

°C/ -20 to +85°C

Ambient/Storage

Humidity

90% RH or less (with no condensation)

Vibration/Shock

Resistance

4.9 m/s

2

/ 19.6 m/s

2

Protection Class/

Pollution Degree

Protection class: IP10, Pollution degree: 2
An environment that satisfies the following conditions.

• Free of corrosive or explosive gases
• Free of exposure to water, oil or chemicals
• Free of dust, salts or iron dust

Altitude

1000 m or less

Others

Free of static electricity, strong electromagnetic fields, magnetic fields or
exposure to radioactivity

Applicable Standards

UL508C
EN50178, EN55011 group 1 class A, EN61000-6-2, EN61800-3, EN61800-
5-1, EN954-1, IEC61508-1 to 4

Configuration

Base-mounted

*1

Perfor-

mance

Speed Control Range

1:5000

Speed

Regu-
lation

∗2

Load

Fluctuation

0 to 100% load:

±0.01% max. (at rated speed)

Voltage

Fluctuation

Rated voltage

±10%: 0% (at rated speed)

Temperature

Fluctuation

25

± 25

°

C:

±0.1% max. (at rated speed)

Torque Control

Tolerance

(Repeatability)

±1%

I/O

Signals

Encoder Output Pulses

Phase-A, -B, -C: line driver
Encoder output pulse: any setting ratio

Sequence

Input

Input

Signals

which can

be allocated

Number

of

Channels

7 channels

Functions

The signal allocation and positive/negative logic can be
modified.

Forward run prohibited (P-OT), reverse run prohibited (N-
OT), forward external torque limit (/P-CL), reverse external
torque limit (/N-CL), general-purpose input signal (/SI0 to /
SI6)

*3

Sequence

Output

Fixed

Output

Servo alarm (ALM)

Output

Signals

which can

be allocated

Number

of

Channels

3 channels

Functions

The signal allocation and positive/negative logic can be modi-
fied.

Positioning completion (/COIN), speed coincidence detection
(/V-CMP), servomotor rotation detection (/TGON), servo
ready (/S-RDY), torque limit detection (/CLT), speed limit
detection (/VLT), brake (/BK), warning (/WARN), near (/
NEAR)