5 connecting a safety device, 1) connector type a 1 – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors User Manual

Page 136

Advertising
background image

4.6 Safety Function

4-53

Operation

4.6.5 Connecting a Safety Device

There are two types of the safety function’s jumper connectors that are attached to SERVOPACKs. You must

remove the safety function’s jumper connector before connecting a safety function device. The connection

method depends on the connector type that is used. Read the following procedures well before you attach a
safety function device.

Use the following procedures to attach safety function devices.

(1) Connector Type A

1.

Remove the servomotor connection terminal connector while pressing the lock.

Applicable SERVOPACKs:
SGDV-R70F, -R90F, -2R1F, -R70A, -R90A, -1R6A, -2R8A, -1R9D, -3R5D, -5R4D

For SERVOPACK models not listed above, it is not necessary to remove the servomotor connection ter-

minal connector. Go to step 2.

2.

Slide the lock injector of the safety function’s jumper connector to the SERVOPACK side to
unlock and remove the safety function’s jumper connector.

Note: The safety function’s jumper connector may be damaged if removed while the lock is still on.

Connector Type A

Connector Type B

Enlarged View

Servomotor
connection
terminal connector

Lock

2. Remove the servomotor

connection terminal connector
while pressing the lock.

1. Press the lock.

Lock injector

Safety function’s
jumper connector

Enlarged View

Remove the safety function’s
jumper connector while the lock
injector is slid to the SERVOPACK
side.

2.

1. Slide the lock injector
to the SERVOPACK
side.

Advertising