5.6 Commands

■■■■■■■■■■■■■■■■■■■■■■

994

■■■■■■■■

tiamo 2.3 Patch 1

Titrino
Range

0 ... 9999 s

Default value

600 s

Measuring interval

Time interval for entering a measuring point in the measuring point list.

Titrando, 855, 867
Range

0.1 ... 999999.0 s (Increment: 0.1)

Default value

2.0 s

Titrino
Range

0.08 ... 16200 s (Increment: 0.08)

Default value

2.0 s

Stop measured value

Stop when the entered measured value has been reached since the start
of the measurement.

Titrando, 855, 867
Range

-20.0 ... 150.0 °C

Selection

off

Default value

off

off
No stop.

Temperature

Temperature

Measuring temperature which can be entered manually. If a temperature
sensor is connected and the Temperature measurement is set on the
General/Hardware tab under Sensor to automatic or continuous,
then the temperature will be measured continuously.

Titrando, 855, 867
Range

-20.0 ... 150 °C

Default value

25.0 °C

Titrino
Range

-170.0 ... 500 °C

Default value

25.0 °C