Metrohm tiamo 2.3 Patch 1 User Manual

Page 34

Advertising
background image

1.11 What is new in tiamo 2.3 Patch 1?

■■■■■■■■■■■■■■■■■■■■■■

18

■■■■■■■■

tiamo 2.3 Patch 1

If a determination was carried out with the 089 Photometer, then the
blank value was not subtracted in the database from the raw data IME
and EME (initial and end measured values, respectively) associated
with the commands MEAS Opt and MEAS Opt Conc.

If determinations that were linked with one another statistically that
also contained as results such things as the slope, the axis intercept
and the correlation coefficient for linear regressions (variables SLO,
ITC, COR) were recalculated in such a way that a determination or a
result was switched off, then the recalculated results of slope, axis
intercept and correlation were not correct.

Program part Method

An 867 pH module present in the device configuration could in fact be
selected as Device type in the command ELT MEAS, but not as
Device name. This led to a situation where the electrode test could
not be carried out with the 867 pH module.

The description of Fill automatically at end was not correct in the
online help for the ADD command.

Program part Configuration

If a barcode reader and a balance were included first in the device con-
figuration for the light version, then it was no longer possible to
include Metrohm devices.

The incorrect text designation for the colorimetric sensors was used
(Sensor instead of Colorimetric sensor) in the user management
under "Access rights for Group 'Group designation', Configuration,
Functions".

The online help for the dialog window Limit values for colorimetric
sensor – 'Name of the colorimetric sensor'
was not available.

After a pH calibration, the calibration date is also entered on the tab
Calibration data with the sensors, among other things. If, after a suc-
cessful calibration, the intelligent sensor as deleted from the configura-
tion and then included again, then the Date ELT could be seen in the
field Calibration date.

In the online help for Export configuration data and Import con-
figuration data
, the descriptions for Export templates and Elec-
trode type templates
were not available.

If one cannot log in within the number of attempts specified in the
security settings and if at the same time the option Message by e-
mail
is active, then an E-mail will be sent to the specified address. Cli-
ent name
was output as text in the subject line of this E-mail, for
which the associated value corresponded to the name of the com-
puter; Client name was replaced by Computer name.