Automation, Magicq automation window, Autom events – ChamSys MagicQ User Manual User Manual

Page 185: 21 automation, 1 magicq automation window, 1 autom events, Chapter 21

Advertising
background image

MagicQ User Manual

156 / 355

Chapter 21

Automation

21.1

MagicQ Automation Window

MagicQ supports an automation system to enable it to automatically respond to both external, internal and timed events. MagicQ
can trigger on external events such as MIDI notes, DMX input, serial input, timecode, and the remote contact input. MagicQ can
also trigger on internal events such as system startup, system shutdown and system powerfail. In addition MagicQ can trigger on
timed (scheduled) events.

MagicQ supports an Automation Window for managing all of the automated events. The Automation Window supports multiple
events with each event being subject to specified parameters.

Each event then triggers a particular MagicQ function – this can be a function on a Playback, a Cue Stack, a Cue, a Page, a Macro
or a Layout.

MagicQ can take a parameter from the event trigger and pass it to the function – for example, it could take the velocity from a
MIDI note event and tigger a Playback level using that velocity.

21.1.1

Autom Events

Each event can have up to 3 paramters (P1,P2,P3) to filter the event further.

Event

P1

P2

P3

Scheduled

Time, Date mask

MIDI note

Mode - on, off or both

Note

Channel – 0 for all

MIDI sysex
Timecode

Start timecode range

End timecode range

Remote

Mode - on, off or both

DMX

Level

Channel

Serial port

number of characters to
match

P2 is characterstring

P3 is the character to pass
to the function

Startup
Shutdown