10 registering device data [save, Registering device data – IDK MSD-54 Series User Manual

Page 104

Advertising
background image

MSD-54 SERIES User’s Guide

104

8.6.10 Registering device data [SAVE]

You can register the set input timings of analog input as the device data.

From the next time, the convert operation will be performed with the registered timings when the same signal

is input from a different channel.

Note:

Do not turn off the MSD while “NOW SAVING...” is displayed in the MSD’s VFD screen; otherwise, the set

data may be lost.

1.

To register the device data using menu:

MSD-5404

Top

↓ SET key

[FUNCTION SELECT]
INPUT TIMING

▲▼keys: Select “INPUT TIMING”.

↓ SET key

[INPUT TIMING]
SAVE

▲▼keys: Select “SAVE”.

↓ SET key ↑ ESC key: Returns to the previous screen without saving settings.

[IN6 SAVE]
No.

1

▲▼keys: Select the desired table number (1 to 99).

◄►keys: Moves the cursor to the device data name.

◄►keys

[IN6 SAVE]
No. 1

▲▼keys: Set the device data name (20 to 7D of 9 ASCII codes”).
◄►keys: Moves the cursor to the next character.

Select the desired input (IN6 to IN9).

↓ SET key: Displays the confirmation screen before saving settings ↑ ESC key

[TIMING TABLE 1]
SAVE? =

N

O

▲▼keys: Select “YES” or “NO”.

↓ To apply the setting: Select “YES” and press the “SET” key.

To return to the menu without any change: Select “NO” and press the “SET” key.

[TIMING TABLE 1]
NOW SAVING...

Displays the message for 1 second before automatically returning to

the previous screen.

[INPUT TIMING]
SAVE

Note:

Device data can be registered only if analog RGB or analog YPbPr signals are

input. You cannot register data and the message shown right is displayed in the

followings cases: analog video signals are input, no signal is input, or video input is set to a channel other

than IN6 to IN9.

IN 1

IN 2

IN 3

IN 4

IN 5

IN 6

IN 7

IN 8

IN 9

N/A

N/A

N/A

N/A

N/A

A

A

A

A

A: Can be registered only if analog RGB/analog YPbPr signals are input.

N/A: Cannot be registered.

2. To registering the device data using commands:

@STT: Register device data

[IN6 SAVE]
NOT AVAILABLE NOW

For each input port/input signal