15 tally, Tally – IDK MSD-54 Series User Manual

Page 209

Advertising
background image

209

8.15 Tally

The maximum supply current of the internal power supply (pins 1 and 26) is 300 mA. Do not use the external

and internal power supplies at the same time. The maximum load capacity of Tally output varies depending

on pin numbers:

Pins 2 to 21 and 27 to 46: DC 48 V, 50 mA

Pins 22 to 24 and 47 to 49: DC 48 V, 1 A

*

* You can use pins 22 to 24 and 47 to 49 to control peripheral devices in settings of8.12 Control Command

Settings”.

Amphenol full pitch 50 pin (female)

(MSD-5404 rear side)

50

26

25

1

25, 50

GND

27 to 49

Pin number

Function

1, 26

2 to 24

+5 V (4.5 V to 5.5 V)

Functions can be assigned

[Figure 8.62] Pin assignment of Tally output connector

2nd pin

3rd pin

4th pin

5th pin

25th pin

1st pin

+5 V (4.5 V to 5.5 V)

Inside MSD-5404

300 mA

2nd pin

3rd pin

4th pin

5th pin

25th pin

1st pin

Inside MSD-5404

300 mA

External power supply

(DC +48 V max)

+5V (4.5V to 5.5V)

[Figure 8.63] Circuit example of Tally

output (Internal power supply)

[Figure 8.64] Circuit example of Tally

output (External power supply)

Advertising