1 the total number of horizontal dots, H total dots, The total number of horizontal dots – IDK MSD-54 Series User Manual

Page 91

Advertising
background image

91

8.6.1 The total number of horizontal dots

[H TOTAL DOTS]

You can set the total number of horizontal dots of analog RGB/analog YPbPr input video videos.

・The total number of horizontal dots: 400 to 4125 (Within sampling clock 13 MHz to 162 MHz)

[Default]: Depends on input signals

[Figure 8.31] Total number of horizontal dots

1. To set the total number of horizontal dots using menu:

Top

↓ SET key

▲▼keys: Select “INPUT TIMING”.

↓ SET key

▲▼keys: Select “H TOTAL DOTS”.

↓ SET key

▲▼keys: Set the total number of horizontal dots.
◄►keys: Select the desired input (IN1 to IN9).

↓ ESC key: Returns to the previous screen.


Note:

You can set the total number of horizontal dots only if analog RGB or analog YPbPr signals are input. You can

only display the set value for input analog video signals or digital input signals, and you cannot change the

setting. If no signal is input, you cannot set the function and a message is displayed.

[IN6 H TOTAL DOTS]
NOT AVAILABLE NOW

A: Settable only if analog RGB/analog YPbPr signals are input.

If analog video signals are input, only the set value is displayed and you cannot set

the total number of horizontal dots.

B: Only the set value is displayed. You cannot set the total number of horizontal dots.

2. To set the total number of horizontal dots using commands:

@SHT: Set the total number of horizontal dots

@GHT: Get the total number of horizontal dots

MSD-5404

[FUNCTION SELECT]
INPUT TIMING

[INPUT TIMING]
H TOTAL DOTS

[IN6 H TOTAL DOTS]
134

4

DOT

IN1

IN2

IN3

IN4

IN5

I 6

IN7

IN8

IN9

A

A

A

A

A

B

B

B

B

Horizontal
synchronizing signal

Video signals

Total horizontal dots = Dots per line

For each input port/input signal

Advertising