*1

Normally, select ”NORMAL MODE” (Automatic measurement of start position and display period). If edges

of video are not displayed correctly, use this mode to set the start position and display period automatically.

The right and bottom edges are cut off and automatic
measurement is performed with “NORMAL MODE”.

If display period is not correct and edges are cut off (even
if the shift starting position is correct), the display period
will be set automatically.

[Figure 8.37] Automatic measurement with “NORMAL MODE”

If the total number of horizontal dots is not correct, the aspect ratio is not matched even though automatic

measurement is set to perform the “NORMAL MODE”. In this case, please select ”NEXT ASPECT” (Auto

measurement taking into account aspect ratio) for the measurement function. Each time you press the “SET”

key, input timing is set based on several aspect ratios of the input signals. If the aspect ratio of the input signal

is known, you can directly specify the aspect ratio to correctly perform the automatic measurement.

If input signal is not registered in the MSD, use this function.

[Figure 8.38] Auto measurement with “NEXT ASPECT”

If you set only start position, the message, “NORMAL END” is displayed. If the

display period is changed with “NORMAL MODE” or if you specify “NEXT ASPECT”

or aspect ratio directly, the set resolution is displayed.

In case aspect ratio does not match or video is displayed on the position far from the correct position, set the

input timing in 8.6.1 The total number of horizontal dots, “8.6.2 Horizontal start position, “8.6.3

Horizontal display period, “8.6.4 Vertical start position, and “8.6.5 Vertical display period“.

You can execute the automatic measurement not only from this menu but also by pressing an input selection

key (one of IN6 to IN9 keys) for 2 seconds or longer. By pressing an input selection key for 2 seconds, the

auto measurement mode with ”NORMAL MODE” will be enabled. After that, pressing the same key for 3

seconds or longer, the auto measurement mode with “NEXT ASPECT” will be enabled. (This auto

measurement mode can be enabled also by pressing the input key for 5 seconds or longer continuously.)

Once you perform the function, from the next time, it can be performed simply by pressing the key without

pressing it for several seconds. This mode can be canceled 5 seconds after the last auto measurement is

executed. If you execute the automatic measurement with this mode, the input selection keys blink until the

measurement finishes.

You can execute the automatic measurement also from input selection keys of parallel input.

[IN6 AUTO SETUP]
1024x 768 60.00Hz

Each time auto measuring is performed, input timing is set in order from some aspect ratios.