2 horizontal start position [h start, Horizontal start position – IDK MSD-54 Series User Manual

Page 92

Advertising
background image

MSD-54 SERIES User’s Guide

92

8.6.2 Horizontal start position [H START]

・Starting position of horizontal reading:

64 to 2900 (Must be equal or less than [The total number of horizontal dots - Horizontal display

period])

[Default]: Depends on input signals

Horizontal
synchronizing signals

Video signals

Horizontal start position = The number of dots from horizontal synchronous signal start to video signal start

Horizontal display

period

Total horizontal dots

[Figure 8.32] Horizontal start position

The settable range depends on settings of 8.6.1 The total number of horizontal dotsand 8.6.3

Horizontal display period.

If the set value is [Total number of horizontal dots > Horizontal display period >

Horizontal start position] and the set value of the horizontal start position exceeds the limit value by changing

the total number of horizontal dots or horizontal display period, set the horizontal start position to the limit

value automatically.

1. To set the horizontal start position using menu:

Top

↓ SET key

▲▼keys: Select “INPUT TIMING”.

↓ SET key

▲▼keys: Select “H START”.

↓ SET key

▲▼keys: Set the horizontal start position.
◄►keys: Select the desired input (IN1 to IN9).

↓ ESC key: Returns to the previous screen.

Note:

You can set the horizontal start position only if there is an input signal. If no

signal is input, you cannot set the position, and the message shown right is

displayed.

2. To set the horizontal start position using commands:

@SHS: Set horizontal start position

@GHS: Get horizontal start position

MSD-5404

[FUNCTION SELECT]
INPUT TIMING

[INPUT TIMING]
H START

[IN6 H START]
29

6

DOT

[IN6 H START]
NOT AVAILABLE NOW

For each input port/input signal

Advertising