1 assigning functions [function assign, Assigning functions, 1 assigning functions ” t – IDK MSD-54 Series User Manual

Page 210

Advertising
background image

MSD-54 SERIES User’s Guide

210

8.15.1 Assigning functions [FUNCTION ASSIGN]

1. To assign functions to Tally output connectors using menu:

MSD-5404

Top

↓ SET key

[FUNCTION SELECT]
TALLY

▲▼keys: Select “Tally”.

↓ SET key

[TALLY]
FUNCTION ASSIGN

▲▼keys: Select “FUNCTION ASSIGN”.

↓ SET key ↑ ESC key: Cancels the setting and returns to the previous screen.

[TALLY PIN: 2]

O

UT1-IN1

▲▼keys: Select the desired function for input pin 2.

*

◄►keys

[TALLY PIN:49]

N

OT USE

▲▼keys: Select the desired function for input pin 49.

*

↓ SET key: Applies settings.

[TALLY FUNCTION]
NOW UPDATE...

Displays the message for 1 second before automatically returning to

the previous screen.

[TALLY]
FUNCTION ASSIGN

* You cannot assign functions to the following pins, and they are not displayed: Pins1, 25, 26, and 50.

Note:

If you do not press the “SET” key, the assignment is not changed. Make sure to press the “SET” key.

2. To assign functions to Tally output connectors using commands:

@STE: Set function assignment of Tally output

@GTE Get function assignment of Tally output

Advertising