Operation with rated power (normal operation)

9300

Mains choke

Interference voltage category according to EN 61800−3 and motor cable length

Component

Component

Type

C2

max. [m]

C1

max. [m]

EVF9321−xV

EZN3A2400H002

EZN3A2400H002

5

EZN3B2400H002

50

EVF9322−xV

EZN3A1500H003

EZN3A1500H003

5

EZN3B1500H003

50

EVF9323−xV

EZN3A0900H004

EZN3A0900H004

5

EZN3B0900H004

50

EVF9324−xV

EZN3A0500H007

EZN3A0500H007

5

EZN3B0500H007

50

EVF9325−xV

EZN3A0300H013

EZN3A0300H013

5

EZN3B0300H013

50

EVF9326−xV

ELN3−0150H024−001

EZN3A0150H024

5

EZN3B0150H024

50

Operation with increased rated power

9300

Mains choke

Interference voltage category according to EN 61800−3 and motor cable length

Component

Component

Type

C2

max. [m]

C1

max. [m]

EVF9321−xV

EZN3A2400H002

EZN3A2400H002

5

EZN3B2400H002

50

EVF9322−xV

EZN3A1500H003

EZN3A1500H003

5

EZN3B1500H003

50

EVF9323−xV

EZN3A0750H005

EZN3A0750H005

5

EZN3B0750H005

50

EVF9324−xV

EZN3A0400H009

EZN3A0400H009

5

EZN3B0400H009

50

EVF9325−xV

EZN3A0300H013

EZN3A0300H013

5

EZN3B0250H015

50