2 device protection, 3 motor protection, Device protection – Lenze EVF9333−xV User Manual

Page 83: Motor protection, Wiring of the standard device

Advertising
background image

Wiring of the standard device

Important notes

Device protection

5

5.1

5.1.2

l

5.1−3

EDSVF9333V EN 6.2−04/2012

5.1.2

Device protection

ƒ In the event of condensation, only connect the controller to the mains

voltage after the humidity has evaporated.

ƒ The controller is protected by external fuses.

ƒ Drive controllers EVF9324−xV, EVF9326−xV and

EVF9328−xV ... EVF9333−xV must only be operated with assigned mains
choke / mains filter.

ƒ Length of the screws for connecting the shield sheet for the control

cables: 12 mm.

ƒ Provide unused control inputs and outputs with terminal strips. Cover

unused Sub−D sockets with protective covers included in the scope of
supply.

ƒ Switching on the motor side of the controller is only permissible for

safety shutdown (emergency−off).

ƒ Frequent mains switching (e.g. inching mode via mains contactor) can

overload and destroy the input current limitation of the drive
controller:
– At least 3 minutes must pass between switching off and restarting

the devices EVF9321−xV and EVF9322−xV.

– At least 3 minutes must pass between two starting procedures of the

devices EVF9323−xV ... EVF9333−xV.

– Use the "safe torque off" safety function (STO) if safety−related mains

disconnections occur frequently. The drive variants Vxx4 are
equipped with this function.

5.1.3

Motor protection

ƒ Extensive protection against overload:

– By overcurrent relays or temperature monitoring.
– We recommend the use of PTC thermistors or thermostats to monitor

the motor temperature.

– PTC thermistors or thermostats can be connected to the controller.
– For monitoring the motor, we recommend the use of the I

2

xt

monitoring.

ƒ Only use motors with an insulation suitable for the inverter operation:

– Insulation resistance: min. û = 1.5 kV, min. du/dt = 5 kV/

ms

– When using motors with an unknown insulation resistance, please

contact your motor supplier.

Advertising
This manual is related to the following products: