Configuration, Code table – Lenze EVF9333−xV User Manual

Page 416

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−68

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C1341

s

^ Selection list 2

Configuration of digital input
signals, function block PCTRL2

See System
Manual
(extension)

1 CFG: RFG−LOAD

1000 FIXED0

l

HIGH = function of
PCTRL2−RFG−SET is active

2 CFG: I−OFF

1000 FIXED0

l

HIGH = Switches of integral
action component

l

LOW = switches on integral
action component

3 CFG: INACT

1000 FIXED0

l

HIGH = deactivates process
controller

4 CFG: OVERLAY

1000 FIXED0

l

HIGH = Shows influence

l

LOW = hides influence

C1344

−199.99

{0.01 %}

199.99 Function block PCTRL2

l

Display of the signals linked in
C1340

See System
Manual
(extension)

1 DIS: RFG−SET
2 DIS: SET
3 DIS: ACT
4 DIS: INFL

C1345

0

1 Function block PCTRL2

l

Display of the signals linked in
C1341

1 DIS: RFG−LOAD
2 DIS: I−OFF
3 DIS: INACT
4 DIS: OVERLAY

C1350 INT1 function

0

Function selection, function block
INT1

See System
Manual
(extension)

0

PHI >= REF

If INT1−IN

³ INT1−REF, INT1−DOUT

is set to HIGH

1

|PHI| >= |REF|

If |INT1−IN|

³ |INT1−REF|,

INT1−DOUT is set to HIGH

C1351 INT1 scaling

65536

00

65536

{1}

1000000000 Scaling factor, function block INT1

INT1

* AOUT [%] +

INT1

* IN [inc]

C1351

@ 100 %

C1354

s

CFG: REF

1000 FIXED0INC

^ Selection list 3

Input signal configuration

l

Reference value

See System
Manual
(extension)

C1355

s

CFG: IN

1000 FIXEDPHI−0

^ Selection list 4

Configuration of input signal,
function block INT1

l

Angle of rotation

C1356

s

CFG: RESET

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block INT1

l

HIGH = Sets the integrator to 0

C1357 DIS: REF

−2000000000

{1 inc}

2000000000 Function block INT1

l

Display of the signal linked in
C13554

See System
Manual
(extension)

C1358 DIS: IN

−32767

{1 rpm}

32767 Function block INT1

l

Display of the signal linked in
C1355

C1359 DIS: RESET

0

1 Function block INT1

l

Display of the signal linked in
C1356

C1360 INT2 function

0

Function selection, function block
INT2

See System
Manual
(extension)

0

PHI >= REF

If INT2−IN

³ INT2−REF, INT2−DOUT

is set to HIGH

1

|PHI| >= |REF|

If |INT2−IN|

³ |INT2−REF|,

INT2−DOUT is set to HIGH

C1361 INT2 scaling

65536

00

65536

{1}

1000000000 Scaling factor, function block INT2

INT2

* AOUT [%] +

INT2

* IN [inc]

C1361

@ 100 %