Installing of the standard device – Lenze EVF9333−xV User Manual

Page 67

Advertising
background image

Installing of the standard device

Standard devices with a power of 45 kW

Thermally separated mounting (push−through technique)

4

4.3

4.3.3

l

4.3−3

EDSVF9333V EN 6.2−04/2012

4.3.3

Thermally separated mounting (push−through technique)

For mounting in push−through technique, the drive controller of type
EVF93xx−EV must be used. In addition, the mounting set EJ0010 for
push−through technique is required.

d2

d2

d2

d

b

g

a1

a

d1

b1

h

h

c1

c2

c3

c4

e

e1

L

9300vec117

Fig. 4.3−2

Dimensions for thermally separated mounting 45 kW

9300 vector

Dimensions [mm]

Type

a

a1

b

b1

c1

c2

c3

c4

d

d1

d2

e

1)

e1

g

h

EVF9330−EV 373 340 543 510 45 137.5 217.5 310 525 45 145 285 163.5 7

9

1)

For a fieldbus module plugged onto X1, consider mounting space for connecting cables

9300 vector

Dimensions [mm]

Type

Width

Height

EVF9330−EV

320

492

Dimensions

Mounting cutout in control
cabinet

Advertising
This manual is related to the following products: