Configuration, Code table – Lenze EVF9333−xV User Manual

Page 417

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−69

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C1364

s

CFG: REF

1000 FIXED0INC

^ Selection list 3

Input signal configuration

l

Reference value

See System
Manual
(extension)

C1365

s

CFG: IN

1000 FIXEDPHI−0

^ Selection list 4

Configuration of input signal,
function block INT2

l

Angle of rotation

C1366

s

CFG: RESET

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block INT2

l

HIGH = Sets the integrator to 0

C1367 DIS: REF

−2000000000

{1 inc}

2000000000 Function block INT2

l

Display of the signal linked in
C13564

See System
Manual
(extension)

C1368 DIS: IN

−32767

{1 rpm}

32767 Function block INT2

l

Display of the signal linked in
C1365

C1369 DIS: RESET

0

1 Function block INT2

l

Display of the signal linked in
C1366

C1370 FOLL max

100.0

0

0.00

{0.01 %}

199.99 Upper limit, function block FOLL1

l

Upper limit of the ramp
function generator

See System
Manual
(extension)

C1371 FOLL min

−100.0

0

−199.99

{0.01 %}

0.00 Lower limit, function block FOLL1

l

Lower limit of the ramp
function generator

C1372 FOLL Tir

10.0

0.1

{0.1 s}

6000.0 Acceleration time T

ir

and

deceleration time T

if

of the ramp

function generator, function block
FOLL1

C1373 FOLL Tif

10.0

0.1

{0.1 s}

6000.0

C1375

s

^ Selection list 1

Configuration of analog input
signals, function block FOLL1

See System
Manual
(extension)

1 CFG: SIGN

1000 FIXED0%

l

Negative value: signal
characteristic at FOLL1−OUT is
opposed to the one at FOLL1−IN

l

Positive value: signal
characteristic at FOLL1−OUT is
the same as at FOLL1−IN

2 CFG: IN

1000 FIXED0%

If FOLL1−IN > FOLL1−REF, the ramp
function generator starts

3 CFG: REF

1000 FIXED0%

Reference value

4 CFG: LOAD

1000 FIXED0%

Initial value for the ramp function
generator

C1376

s

CFG: SET

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block FOLL1

l

HIGH: initial value at
FOLL1−LOAD is accepted

C1377

−199.99

{0.01 %}

199.99 Function block FOLL1

l

Display of the signals linked in
C1375

See System
Manual
(extension)

1 DIS: SIGN
2 DIS: IN
3 DIS: REF
4 DIS: LOAD

C1378 DIS: SET

0

1 Function block FOLL1

l

Display of the signal linked in
C1376

Advertising
This manual is related to the following products: