Configuration, Code table – Lenze EVF9333−xV User Manual

Page 406

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−58

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0879

Resetting control words

l

C0879 = 1 performs one reset

1 Reset C135

0

0

Ready

2 Reset AIF

0

1

Reset

3 Reset CAN

0

C0880

s

^ Selection list 2

Configuration of digital input
signals, function block DCTRL

l

Select parameter set

l

Selection of a parameter set via
binary coding of the digital
input signals

See System
Manual
(extension)

1 CFG: PAR*1

1000 FIXED0 C0880/1 C0880/2 Selected

parameter set

2 CFG: PAR*2

1000 FIXED0

0

0

Parameter set 1

0

1

Parameter set 2

1

0

Parameter set 3

1

1

Parameter set 4

C0881

s

CFG: PAR−LOAD

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block DCTRL

l

LOW−HIGH edge = Load
selected parameter set into
C0880

See System
Manual
(extension)

C0884

Function block DCTRL

l

Display of the signals linked in
C0880 and C0881

See System
Manual
(extension)

1 DIS: PAR*1
2 DIS: PAR*2
3 DIS: PAR−LOAD

C0885

s

CFG: R

51

DIGIN1

^ Selection list 2

Configuration of digital input
signals, function block R/L/Q

l

Truth table:

Inputs Outputs
R

L

R/L

QSP

0

0

0/1

1

1

0

0

0

0

1

1

0

1

1

˘

˘

˘ State is unchanged

See System
Manual
(extension)

C0886

s

CFG: L

52

DIGIN2

^ Selection list 2

C0889

0

1 Function block R/L/Q

l

Display of the signals linked in
C0885 and C0886

1 DIS: R
2 DIS: L

C0890

s

CFG: N−SET

5050 NSET−NOUT

^ Selection list 1

Configuration of analog input
signal, function block MCTRL

l

Speed setpoint

^
8.2−25

^
8.2−48

C0891

s

CFG: M−Add

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block MCTRL

l

Additional torque setpoint or
torque setpoint

^
8.2−48

C0892

s

CFG: Lo−M−LIM

5700 ANEG1−OUT

^ Selection list 1

Configuration of analog input
signal, function block MCTRL

l

Lower torque limit in [%] of
C0057

C0893

s

CFG: HI−M−LIM

19523 FCODE−472/3

^ Selection list 1

Configuration of analog input
signal, function block MCTRL

l

Upper torque limit in [%] of
C0057

C0898

s

CFG: M−LIM
switch

0

0

M−LIM ON

Reduced torque
limit is active

Torque limitation in the field
weakening range, function block
MCTRL

l

If the torque limit is reduced,
the maximum possible torque
in the field weakening range is
lowered with 1/f. This provides
a higher motor stability in the
field weakening range

^
8.2−48

1

M−LIM OFF

Reduced torque
limit is inactive

Advertising
This manual is related to the following products: