Code table

8

8.5

l

8.5−10

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0091

s

Mot cos phi

à

0.50

{0.01 }

1.00 Motor cos

j

à

depending on C0086

l

Motor selection in C0086 sets
the corresponding motor cos

j

in C0091

l

Change of C0091 sets
C0086 = 0

^ 6.6−1

C0092

s

Mot Ls

à

0.0

{0.1 mH}

6500.0 Motor stator inductance

à

Value is evaluated by motor
parameter identification from
C0088, C0089, C0090 and
C0091

à

Selection of a motor in C0086
sets the corresponding stator
inductance value in C0092

^ 6.6−1

C0093 DRIVE IDENT

Controller identification

l

Read only

0

invalid

Damaged power section

1

none

No power section

9321
...
9333

9321VC
...
9333VC

Display of the controller used

C0094 Password

0

0

{1}

9999 Password

l

C0094 = 1 ... 9999: Free access
to the user menu only

^ 7.2−9

C0095

s

Mot Io

à

0.00

{0.01 A}

1000.00 Motor magnetising current

à

depending on C0086, C0088
and C0091

l

Change of C0086, C0088 and
C0091 sets C0095 to the Lenze
setting

l

Change of C0095 sets
C0086 = 0

^ 6.6−1

^
6.11−5

C0096

0

no protection

No password
protection

Parameter access protection

l

Extension of the access
protection for AIF bus systems
and CAN with activated
password in C0094

l

All codes in the user menu can
continued to be accessed.

1

R protection

Read protection

2

W protection

Write protection

3

R/W protection

Read/write
protection

1 AIF protect.

0

Parameter access protection AIF

2 CAN protect.

0

Parameter access protection CAN

C0099 S/W version

x.y

Software version

l

Read only

x
y

Main version
Subversion

Advertising