Configuration, Code table – Lenze EVF9333−xV User Manual

Page 360

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−12

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0116

s

^ Selection list 2

Configuration of free digital
outputs (FDO)

l

Signals can only be evaluated
when being networked with
automation interfaced

See System
Manual
(extension)

1 CFG: FDO−0

1000 FIXED0

... ...

...

...

32 CFG: FDO−31

1000 FIXED0

C0117

s

^ Selection list 2

Configuration of digital inputs
signals, function block DIGOUT
A change of the basic
configuration in C0005 changes
the signal assignment!

^ 6.5−3

See System
Manual
(extension)

1 CFG: DIGOUT1

15000 DCTRL−TRIP

Terminal X5/A1

2 CFG: DIGOUT2

10650 CMP1−OUT

Terminal X5/A2

3 CFG: DIGOUT3

500

DCTRL−RDY

Terminal X5/A3

4 CFG: DIGOUT4

5003 MCTRL−MMAX

Terminal X5/A4

C0118

0

High active

HIGH level is
active

Inversion of digital output signals,
function block DIGOUT

1

LOW active

LOW level is active

1 DIGOUT1 pol

1

Terminal X5/A1

2 DIGOUT2 pol

1

Terminal X5/A2

3 DIGOUT3 pol

0

Terminal X5/A3

4 DIGOUT4 pol

0

Terminal X5/A4

C0120 OC6 LIMIT

0

00

{1 °C}

120 Threshold for I

2

× t monitoring

(motor).

l

0 = I

2

× t monitoring

switched−off

l

I

2

× t > C0120

ð trip OC6

C0121 OH7 limit

150

45

{1 °C}

150 Setting of the operating

temperature for monitoring OH7

l

Only for KTY at X8

l

Monitoring OH7 is configured
in C0584

^
6.6−10

See System
Manual
(extension)

C0122 OH4 limit

80

45

{1 °C}

85 Configuration of monitoring OH4

l

Monitoring of the heatsink
temperature

l

Activating monitoring with
C0582

l

Temperature in C0122 reached:
– Warning OH4 is initiated

See System
Manual
(extension)

C0125 Baudrate

0

0

9600 baud

LECOM baud rate

l

Baud rate for accessory module
2102

1

4800 baud

2

2400 baud

3

1200 baud

4

19200 baud

C0126 MONIT CE0

3

0

TRIP

Configuration of monitoring CE0

l

Error message in case of
communication error AIF

See System
Manual
(extension)

2

Warning

3

Off

C0127 OC8 LIMIT

0

0

{1 °C}

120 Threshold for I

2

× t advance

warning (motor).

l

0 = I

2

× t advance warning

switched−off

l

I

2

× t > C0127

ð fault message

OC8 (response set in C606)

C0128 TAU MOTOR

5.0

0.1

{0.1 min}

50.0 Thermal time constant of the

motor
The time constant is required for
calculating the I

2

× t

disconnection.