Configuration, Code table – Lenze EVF9333−xV User Manual

Page 364

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−16

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0149

s

Auto ident

0

0

Id
inactive

Automatic identification is
inactive

Automatic motor data
identification
1. Inhibit controller, wait until

drive has stopped

2. Enter the correct values of the

motor nameplate into C0087,
C0088, C0089, C0090, C0091

3. Set C0149 = 1, confirm with

v

4. Enable controller

The identification
– starts,

c goes off. The

motor "whistles" but does
not rotate!

– lasts approx. 1 ... 2 min
– is completed when

c is lit

again

5. Inhibit controller:

^
6.6−14

1

Id active Automatic identification is

active

l

The identification starts
automatically after
controller enable

l

After a faulty
identification, the process
is restarted after TRIP
RESET or mains switching
and subsequent
controller enable

C0150 Status word

Bit00

Bit08

Status code

Read only
Decimal status word for
networking via automation
interface (AIF)

l

Binary interpretation indicates
the bit states

See System
Manual
(extension)

Bit01

IMP

Bit09

Status code

Bit02

Bit10

Status code

Bit03

Bit11

Status code

Bit04

Bit12

Warning

Bit05

Bit13

Message

Bit06

n = 0

Bit14

Bit07

CINH

Bit15

C0151 DIS: FDO (DW)

Read only

l

Free digital outputs (FDO)

l

Hexadecimal representation of
the digital output signals
configured in C0116

l

Binary interpretation indicates
the bit states

See System
Manual
(extension)

C0155 Status word 2

Bit00

Fail

Bit08

R/L

Display only

l

Binary interpretation indicates
the bit states

Bit01

M

max

Bit09

Bit02

I

max

Bit10

Bit03

IMP

Bit11

Bit04

RDY

Bit12

Bit05

CINH

Bit13

Bit06

TRIP

Bit14

Bit07

Init

Bit15