Installing of the standard device

Standard devices in the power range 0.37 ... 11 kW

Thermally separated mounting (push−through technique)

4

4.1

4.1.3

l

4.1−3

EDSVF9333V EN 6.2−04/2012

4.1.3

Thermally separated mounting (push−through technique)

For mounting in push−through technique, the drive controller of type
EVF93xx−EV must be used. In addition, the mounting set for push−through
technique is required.

Type

Mounting set

Type

Mounting set

EVF9321−EV,
EVF9322−EV

EJ0036

EVF9323−EV,
EVF9324−EV

EJ0037

EVF9325−EV,
EVF9326−EV

EJ0038

a1

a1

c1

c1

a

a

c

c

g

g

d1

d1

d1

d1

d

d

b1

b1

b

b

L

L

1

0

e

f

9300vec115

Fig. 4.1−2

Dimensions for thermally separated mounting 0.37 ... 11 kW

9300 vector

Dimensions [mm]

Type

a

a1

b

b1

c

c1

d

d1

e

1)

f

g

EVF9321−EV
EVF9322−EV

0 112.5

78

385.5

350

60

95.5 365.5 105.5

250

92

6.5

EVF9323−EV
EVF9324−EV

0 131.5

97

385.5

350

79

114.5 365.5 105.5

250

92

6.5

EVF9325−EV
EVF9326−EV

1 169.5 135 385.5 350

117

152.5 365.5 105.5

250

92

6.5

1)

For a fieldbus module plugged onto X1, consider mounting space for connecting cables

9300 vector

Dimensions [mm]

Type

Width

Height

EVF9321−EV
EVF9322−EV

0

82

350

EVF9323−EV
EVF9324−EV

0

101

350

EVF9325−EV
EVF9326−EV

1

139

350

Dimensions

Mounting cutout in control
cabinet