Configuration – Lenze EVF9333−xV User Manual

Page 292

Advertising
background image

Configuration

Function blocks
Internal motor control with V/f characteristic control (MCTRL1)

8

8.2
8.2.6

l

8.2−30

EDSVF9333V EN 6.2−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0105 QSP Tif

5.00

0.00

{0.01 s}

999.90 Quick stop deceleration time

l

The deceleration time refers to
a speed variation of C0011 ... 0

^
8.2−25

^
8.2−48

C0107 holding time

0.00

0.00

{0.01 s}

9999.90 Hold time for automatic DC

injection braking (Auto−GSB)

^
8.2−25

^
8.2−48

C0132

s

Controller
enable fly
delay

à

0

{1 ms}

9999 Minimum time for controller

inhibit with active flying restart
circuit, delays the start of the
flying restart process after
controller enable

à

depending on C0082, C0086,
C0087, C0088, C0089, C0090,
C0091, C0092
A change of one of the codes
resets C0132 to the minimum
time of the selected motor

l

The time is derived from the
double rotor time constant

^
8.2−25

^
8.2−48

C0140

s

select direct

0

Search direction during flying
restart process

l

Positive direction of rotation:
The motor rotates in CW
direction with view on the
motor shaft

l

Negative direction of rotation:
The motor rotates in CCW
direction with view on the
motor shaft

^
8.2−25

^
8.2−48

0

NSET

Only search in the direction of the
applied setpoint

1

inv. Nset

Only search against the direction
of the applied setpoint

2

pos.

Only search in positive direction of
rotation

3

neg.

Only search in negative direction
of rotation

4

Both, Nset

Search at first in the direction of
the applied setpoint and then
against the direction

5

Both, inv. Nset

Search at first against the
direction and then in the direction
of the applied setpoint

6

Both pos.

Search at first in positive then in
negative direction of rotation

7

Both neg.

Search at first in negative then in
positive direction of rotation

Advertising
This manual is related to the following products: