Commissioning

Adjusting the motor

Motor temperature monitoring with KTY

6

6.6

6.6.4

l

6.6−11

EDSVF9333V EN 6.2−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0594 MONIT SD6

3

0

TRIP

Activation of the motor
temperature monitoring with KTY
at X8

l

Use C0594 = 0 or 2 to activate
monitoring

l

In case of a short circuit or
interruption at X8/5 and X8/8
the fault message SD6 is
activated

l

Configuration of the response
when exceeding the motor
temperature
– Fixed operating temperature

in C0583

– Variable operating

temperature in C0584

^
6.6−10

See System
Manual
(extension)

2

Warning

3

Off

)

Note!

ƒ

In the Lenze setting, the motor temperature monitoring is
switched off!

ƒ

If you work with several parameter sets, the monitoring must
be activated separately in each parameter set!

Use C0594 = 0 or C0594 = 2 to activate the motor temperature monitoring
via X8. In addition, the connection is monitored for short circuit and
interruption.

1. Connecting the monitoring circuit of the motor to X8/5 and X8/8.

2. Setting controller reaction to short circuit or interruption of the

connection:
– C0594 = 3: Monitoring is switched off.
– C0594 = 0: TRIP error message (display of keypad: Sd6

a)

– C0594 = 2: Warning signal (display of keypad: Sd6

e)

Monitoring with a fixed operating temperature (150 °C)

1. Set response of the controller:

– C0583 = 3: temperature monitoring of the motor switched off.
– C0583 = 0: TRIP error message (keypad display: OH3

a)

– C0583 = 2: warning signal (keypad display: OH3

e)

Monitoring with a variable operating temperature (45...150 °C)

1. Set the operating temperature in C0121.

2. Set response of the controller:

– C0584 = 3: temperature monitoring of the motor switched off.
– C0584 = 2: warning signal (keypad display: OH7

e)

Activation

Adjustment