Configuration – Lenze EVF9333−xV User Manual

Page 307

Advertising
background image

Configuration

Function blocks

Internal motor control with V/f characteristic control (MCTRL1)

8

8.2

8.2.6

l

8.2−45

EDSVF9333V EN 6.2−04/2012

Function procedure 2:

ƒ If you define a speed setpoint > speed threshold (C0019) before the

hold time elapses, DC−injection braking is deactivated and the drive
follows the speed setpoint. If the speed falls below the threshold again,
DC−injection braking is reactivated and the hold time is restarted.

0

1

5

2

3

4



‚

ƒ

„

C0036

C0019

9300vec091

Fig. 8.2−20

Signal characteristic with automatic DC injection braking

0 Speed setpoint (e. g. AIN−OUT)

1 Actual speed value of the motor (e. g. MCTRL−NACT)

2 Controller output current (e. g. MCTRL−IACT)

3 Pulse inhibit (e. g. DCTRL−IMP)

4 DC injection braking is active (MCTRL−GSB−OUT)

MCTRL−GSB−OUT = HIGH: Function is active
MCTRL−GSB−OUT = LOW: Function is not active

 The motor rotates with the preset speed. The current adjusts itself as a

function of the load

5.

‚ With a speed setpoint < speed threshold (C0019), DC injection braking is

activated. Pulse inhibit

c is set. The motor coasts.

ƒ The pulse inhibit is deactivated and the DC braking current set in C0036 is

injected

„ DC−injection braking is deactivated as soon as the speed setpoint exceeds

the speed threshold (C0019). The motor is accelerated to the defined speed
setpoint and kept there.