Configuration, Code table – Lenze EVF9333−xV User Manual

Page 415

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−67

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C1330 PCTRL2 Tir

1.0

0.1

{0.1 s

6000.0 Acceleration time t

ir

, function

block PCTRL2

l

Acceleration time for the
setpoint

l

The acceleration time refers to
a setpoint change of 0 ... 100 %

See System
Manual
(extension)

C1331 PCTRL2 Tif

1.0

0.1

{0.1 s}

6000.0 Deceleration time t

if

, function

block PCTRL2

l

Deceleration time for the
setpoint

l

The deceleration time refers to
a setpoint change of 100 % ... 0

C1332 PCTRL2 Vp

1.0

0.1

{0.1 }

500.0 Gain V

p

, function block PCTRL2

See System
Manual
(extension)

C1333 PCTRL2 Tn

400

20

{1 ms}

99999 Integral−action time T

n

, function

block PCTRL2
Setting of reset time T

n

of PCTRL2

C1334 PCTRL2 Kd

0.0

0.0

{0.1 }

5.0 Differential component K

d

,

function block PCTRL2

C1335 bipolar/

unipolar

0

Sphere of action, function block
PCTRL2

0

Bipolar

l

Output value is limited to
−100 ... 100 %

See System
Manual
(extension)

1

Unipolar

l

Output value is limited to
0 ... 100 %

C1336 Tir overlay

1.0

0.1

{0.1 s}

6000.0 Fade−in time, function block

PCTRL2

l

Acceleration time of the ramp
generator

l

Controls the influence of the
process controller

See System
Manual
(extension)

C1337 Tif overlay

1.0

0.1

{0.1 s}

6000.0 Fade−out time, function block

PCTRL2

l

Deceleration time of the ramp
generator

l

Controls the influence of the
process controller

C1340

s

^ Selection list 1

Configuration of analog input
signals, function block PCTRL2

See System
Manual
(extension)

1 CFG: RFG−SET

1000 FIXED0%

l

The process setpoint is shown
at PCTRL2−SET with a starting
value via a ramp generator

l

PCTRL−RFG−LOAD = HIGH
activates the function

2 CFG: SET

1000 FIXED0%

l

Input for process value

l

Value range: ±200 %

3 CFG: ACT

1000 FIXED0%

l

Input for actual value

l

Value range: ±200 %

4 CFG: INFL

1000 FIXED0%

l

Evaluation (influence) of the
output signal

l

Value range: ±200 %

Advertising