8.5

l

8.5−38

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0603 Function

1

0

OUT = IN1

Function selection, function block
ARIT3

See System
Manual
(extension)

1

OUT = IN1 + IN2

2

OUT = IN1 − IN2

3

OUT = IN1 * IN2

4

OUT = IN1 / IN2

5

OUT = IN1 / (100 − IN2)

C0604

s

^ Selection list 1

Configuration of analog input
signal, function block ARIT3

1 CFG: IN

1000 FIXED0%

ARIT3−IN1

2 CFG: IN

1000 FIXED0%

ARIT3−IN2

C0605

−199.99

{0.01 %}

199.99 Function block ARIT3

l

Display of the signals linked in
C0604

1 DIS: IN

ARIT3−IN1

2 DIS: IN

ARIT3−IN2

C0606 MONIT OC8

2

0
2
3

TRIP
Warning
Off

Configuration of the I

2

× t

advance warning
The threshold is set in C0127.

C0608

s

CFG: IN

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block SQRT1

See System
Manual
(extension)

C0609 DIS: IN

−199.99

{0.01 %}

199.99 Function block SQRT1

l

Display of the signal linked in
C0608

C0610

s

^ Selection list 1

Configuration of analog input
signals, function block ADD1

See System
Manual
(extension)

1 CFG: IN

1000 FIXED0%

Addition input ADD1−IN1

2 CFG: IN

1000 FIXED0%

Addition input ADD1−IN2

3 CFG: IN

1000 FIXED0%

Subtraction input ADD1−IN3

C0611

−199.99

{0.01 %}

199.99 Function block ADD1

l

Display of the signals linked in
C0610

1 DIS: IN

ADD1−IN1

2 DIS: IN

ADD1−IN2

3 DIS: IN

ADD1−IN3

C0612

s

^ Selection list 1

Configuration of analog input
signals, function block ADD2

See System
Manual
(extension)

1 CFG: IN

1000 FIXED0%

Addition input ADD2−IN1

2 CFG: IN

1000 FIXED0%

Addition input ADD2−IN2

3 CFG: IN

1000 FIXED0%

Subtraction input ADD2−IN3

C0613

−199.99

{0.01 %}

199.99 Function block ADD2

l

Display of the signals linked in
C0612

1 DIS: IN

ADD2−IN1

2 DIS: IN

ADD2−IN2

3 DIS: IN

ADD2−IN3

C0620 DB1 gain

1.00

−10.00

{0.01 }

10.00 Gain, function block DB1

See System
Manual
(extension)

C0621 DB1 value

1.00

0.00

{0.01 %}

100.00 Dead band, function block DB1

l

Fault signals around the zero
point of the input signal are set
to 0

C0622

s

CFG: IN

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block DB1

C0623 DIS: IN

−199.99

{0.01 %}

199.99 Function block DB1

l

Display of the signal linked in
C0622