Commissioning

Acceleration, deceleration, braking, stopping

Speed range

6

6.10

6.10.1

l

6.10−1

EDSVF9333V EN 6.2−04/2012

6.10

Acceleration, deceleration, braking, stopping

6.10.1

Speed range

The speed range required for the application is set in the codes C0010 and
C0011:

ƒ The minimum speed (C0010) corresponds to a speed setpoint selection

of 0 %.

ƒ The minimum speed (C0011) corresponds to a speed setpoint selection

of 100 %.

n

0 %

100 %

C0011

C0010

9300vec097

Fig. 6.10−1

Relation between setpoint and minimum and maximum output frequency

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0010 N

min

0

0

{1 rpm}

36000

l

Reference value
for the absolute
and relative
setpoint selection
for the
acceleration and
deceleration
times

l

C0059 must be
set correctly

l

Set C0010 <
C0011

l

C0010 is only
effective in case
of analog setpoint
selection via AIN1

Important: For
parameter setting
via interface, major
changes in one step
should only be made
when the controller
is inhibited.

Minimum
speed

^
6.10−1

C0011 N

max

3000 0

{1 rpm}

36000

Maximum
speed

Features of "minimum speed" (n

min

):

ƒ C0010 is approached via the acceleration ramp.

ƒ C0010 is only effective with analog setpoint selection via AIN1

(terminal X6/1 and X6/2).

Description

C0010