Commissioning – Lenze EVF9333−xV User Manual

Page 224

Advertising
background image

Commissioning

Switching frequency of the inverter

6

6.9

l

6.9−2

EDSVF9333V EN 6.2−04/2012

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0018 fchop

6

Switching frequency of the
inverter

l

General rule: the lower the
switching frequency the
– lower the power loss
– higher the noise generation
– better the concentricity

factor

– Observe derating

information at high
switching frequencies

l

The max. output frequency
(f

out

) amounts to:

– f

chop

= 16 kHz

Þf

out

= 600 Hz

– f

chop

= 8 kHz

Þf

out

= 300 Hz

– f

chop

= 4 kHz

Þf

out

= 150 Hz

– f

chop

= 2 kHz

Þf

out

= 150 Hz

^
6.9−1

0

auto chop

automatic
change−over of the
switching
frequency
between
16/8/2 kHz

1

2 kHz sin

optimised smooth
running

2

4 kHz f_top

power−optimised

3

8 kHz f_top

power−optimised

4

8 kHz sin

noise optimised

5

16 kHz sin

noise optimised

6

auto 8/2 kHz

noise /
power−optimised
with automatic
change−over to
low switching
frequency

C0144

s

OH switch

1

0

Switch off

Switch−over is not
active

Temperature−dependent
switching frequency reduction

l

If the heatsink temperature set
in C0122 is reached (warning

OH4), the controller switches
to 2 kHz

1

Switch on

Switch−over is
active

C0144 = 0 (no temperature−dependent switching frequency reduction)

If the maximum permissible heatsink temperature (

J

max

) is exceeded when

operating with automatic switching frequency reduction, the inverter is
inhibited, TRIP "OH" (overtemperature) is set and the motor coasts without
torque.

C0144 = 1 (temperature−dependent switching frequency reduction is
active):

ƒ If the heatsink temperature set in C0122 (overtemperature OH4) is

reached when operating with automatic switching frequency
reduction, the controller automatically reduces the switching
frequency to 2 kHz, thus keeping the operation running.

ƒ After the heatsink has cooled down, the controller automatically

switches to the set switching frequency again.

Function of automatic
switching frequency
reduction

Advertising
This manual is related to the following products: