Technical data

General data and operating conditions

3

3.1

l

3.1−1

EDSVF9333V EN 6.2−04/2012

3.1

General data and operating conditions

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

2004/108/EG

EMC Directive

Approval

UL

cULus

Power Conversion Equipment (File No. E132659)

Protection of persons and equipment

Type of protection

EN 60529

IP20

IP41 in case of thermally separated installation
(push−through technique) between the control
cabinet (inside) and the environment.

NEMA 250

Protection against accidental contact in accordance
with type 1

Earth leakage current IEC/EN 61800−5−1 > 3.5 mA

Observe regulations and
safety instructions!

Insulation of control
circuits

IEC/EN 61800−5−1 Safe mains isolation by double (reinforced)

insulation for the terminals X1 and X5.
Basic insulation (single isolating distance) for the
terminals X3, X4, X6, X8, X9, X10 and X11.

Insulation resistance

EN 61800−5−1

< 2000 m site altitude: Overvoltage category III

> 2000 m site altitude: Overvoltage category II

Protective measures

Against short circuit, earth fault (earth−fault
protected during operation, limited earth−fault
protection during operation), overvoltage, motor
stalling, motor overtemperature (input for PTC or
thermal contact)

EMC

Noise emission

IEC/EN 61800−3

Cable−guided, up to 10 m motor cable length with
mains filter A: category C2.

Radiation, with mains filter A and installation in
control cabinet: category C2

Interference
immunity

IEC/EN 61800−3

Category C3

Ambient conditions

Climatic

Storage

IEC/EN 60721−3−1 1K3 (−25 ... +55 °C)

< 6 months

1K3 (−25 ... +40 °C)

> 6 months
> 2 years: form DC bus
capacitors

Transport

IEC/EN 60721−3−2 2K3 (−25 ... +70 °C)

Operation

EVF9321 ...
EVF9326

IEC/EN 60721−3−3 3K3 (0 ... +55 °C)

> +40 °C: reduce the rated output current by
2.5 %/°C.

EVF9327 ...
EVF9333

3K3 (0 ... +50 °C)
> +40 °C: reduce the rated output current by
2.5 %/°C.

Pollution

IEC/EN 61800−5−1 Degree of pollution 2

General data