Function blocks
Internal motor control with vector control (MCTRL2)

8

8.2
8.2.7

l

8.2−52

EDSVF9333V EN 6.2−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0079 Adapt I−CTRL

100.0

0

10.00

{0.01 %}

100.00 Adaption of the current controller

l

Evaluation for the reset time
T

ni

of the current controller

l

Effective for setpoint = 0

l

Is increased automatically to
100 % up to rated speed

l

C0079 = 100 %: no adaption of
the reset time

l

C0079 < 100 %:
– evaluation of the reset time:

^
8.2−25

^
8.2−48

C0082

s

Mot Rr

à

0.000

{0.001

W}

65.000 Motor rotor resistance

à

Value is evaluated by motor
parameter identification from
C0087, C0088, C0089, C0090
and C0091

l

Selection of a motor in C0086
sets the corresponding rotor
resistance value

^ 6.6−1

^
6.6−14

C0084

s

Mot Rs

à

0.00

{0.01 m

W}

100000.

00

Motor stator resistance

à

Value is determined by motor
parameter identification
(C0148, C0149)

^ 6.6−1

^
6.6−14

C0085

s

Mot Lss

à

0.0

{0.1 mH}

6500.0 Motor leakage inductance

à

Value is evaluated by motor
parameter identification
(C0148, C0149)

^ 6.6−1

^
6.6−14

C0086

s

Mot type

à

^ Motor selection list

Motor type selection

à

depending on the controller
used

l

Motor selection in C0086 sets
the corresponding parameters
in C0021, C0022, C0081,
C0087, C0088, C0089, C0090,
C0091

^ 6.6−1

C0087

s

Mot speed

à

50

{1 rpm}

36000 Rated motor speed

à

depending on C0086

l

Motor selection in C0086 set
the corresponding rated motor
speed in C0087

l

Change of C0087 sets
C0086 = 0

^ 6.6−1

C0088

s

MOT CURRENT

à

0.5

{0.1 A}

500.0 Rated motor current

à

Depending on C0086

l

Selection of a motor in C0086
sets the corresponding rated
motor current in C0088

l

Change of C0088 sets
C0086 = 0

^ 6.6−1

C0089

s

Mot frequency

à

10

{1 Hz}

5000 Rated motor frequency

à

depending on C0086

l

Motor selection in C0086 sets
the corresponding rated motor
frequency in C0089

l

Change of C0089 sets
C0086 = 0

^ 6.6−1

C0090

s

Mot voltage

à

0

{1 V}

1000 Rated motor voltage

à

depending on C0086

l

Motor selection in C0086 sets
the corresponding rated motor
voltage in C0090

l

Change of C0090 sets C0086 =
0

^ 6.6−1