Troubleshooting and fault elimination

Display of operating data, diagnostics
Diagnostics

9

9.1
9.1.2

l

9.1−2

EDSVF9333V EN 6.2−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0064 Utilization

0

{1 %}

150 Device utilisation I×t

l

Read only

l

Device utilisation during the
last 180 s of operating time

l

C0064 > 100 % releases
warning OC5

l

C0064 > 140 % limits the
output current of the controller
to 67 % of the maximum
current in C0022

^
8.2−25

^
8.2−48

C0150 Status word

Bit00

Bit08

Status code

Read only
Decimal status word for
networking via automation
interface (AIF)

l

Binary interpretation indicates
the bit states

See System
Manual
(extension)

Bit01

IMP

Bit09

Status code

Bit02

Bit10

Status code

Bit03

Bit11

Status code

Bit04

Bit12

Warning

Bit05

Bit13

Message

Bit06

n = 0

Bit14

Bit07

CINH

Bit15

9.1.2

Diagnostics

Display codes for diagnostics

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0093 DRIVE IDENT

Controller identification

l

Read only

0

invalid

Damaged power section

1

none

No power section

9321
...
9333

9321VC
...
9333VC

Display of the controller used

C0099 S/W version

x.y

Software version

l

Read only

x
y

Main version
Subversion