Configuration – Lenze EVF9333−xV User Manual
Page 365
![background image](/manuals/566191/365/background.png)
Configuration
Code table
8.5
l
8.5−17
EDSVF9333V EN 4.0−11/2007
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0156
s
^ Selection list 2
Configuration of digital input
signals of function block STAT
l
Input signals are output as
status messages in C0150, AIF
status word and CAN1 status
word
See System
Manual
(extension)
1 CFG: STAT.B0
2000 DCTRL−PAR*1−O
2 CFG: STAT.B2
5002 MCTRL−IMAX
3 CFG: STAT.B3
5003 MCTRL−MMAX
4 CFG: STAT.B4
5050 NSET−RFG I=O
5 CFG: STAT.B5
10650 CMP1−OUT
6 CFG: STAT.B14
505
DCTRL−CW/CCW
7 CFG: STAT.B15
500
DCTRL−RDY
C0157
0
1
No status message
Status message is output
Digital status signal of function
block STAT
l
Display of the signals linked in
C0156
1 DIS: STAT.B0
2 DIS: STAT.B2
3 DIS: STAT.B3
4 DIS: STAT.B4
5 DIS: STAT.B5
6 DIS: STAT.B14
7 DIS: STAT.B15
C0161 Act trip
Display of history buffer "Active
fault"
l
Keypad: LECOM error number
See System
Manual
(extension)
C0167 Reset failmem
0
0
Ready
Clear history buffer
l
Active fault messages are not
cleared
See System
Manual
(extension)
1
Clear history buffer