Configuration

Function blocks

Master frequency output (DFOUT)

8

8.2

8.2.3

l

8.2−9

EDSVF9333V EN 6.2−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0540

s

Function

0

Function selection, function block
DFOUT

l

Output signal at X10

^
8.2−8

0

Analog input

Analog input

Signal at DFOUT−AN−IN is output.
Zero track can be input externally.

1

PH diff input

Phase difference
input

Signal at DFOUT−DF−IN is output.
Zero track can be input externally.

2

Not assigned

3

Not assigned

4

X10 = X9

X9 is output on
X10

The input signals are buffered
C0030 is without function

5

X10 = X8

X8 is output on
X10

C0541

s

CFG: AN−IN

5001 MCTRL−NACT

^ Selection list 1

Configuration of analog input
signal, function block DFOUT

l

Signal in [%] of C0011

C0542

s

CFG: DF−IN

1000 FIXEDPHI−0

^ Selection list 4

Configuration of input signal,
function block DFOUT

l

Speed signal

C0544

s

CFG: SYN−RDY

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block DFOUT

l

DFOUT−SYN−RDY = HIGH:
Generating a zero pulse

C0545 PH offset

0

0

{1 inc.}

65535 Phase offset, function block

DFOUT

l

Displacing the zero pulse
generated via DFOUT−SYN−RDY
by up to 360 °

l

1 rev. = 65535 inc (360 °)