Configuration – Lenze EVF9333−xV User Manual

Page 293

Advertising
background image

Configuration

Function blocks

Internal motor control with V/f characteristic control (MCTRL1)

8

8.2

8.2.6

l

8.2−31

EDSVF9333V EN 6.2−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0142 Start options

1

Starting condition for the flying
restart circuit

^
8.2−36

^
8.2−65

0

Start lock

l

Automatic start is inhibited
after
– mains connection
– Cancel of a message

(t > 0.5 s)

– Trip reset

l

Flying restart circuit is inactive

l

Start after HIGH−LOW−HIGH
level change at X5/28

1

Auto start

Automatic start when
X5/28 = HIGH

l

Flying restart circuit is inactive

2

flying lock

l

Automatic start is inhibited
after
– mains connection
– Cancel of a message

(t > 0.5 s)

– Trip reset

l

Flying restart circuit is active

l

Start after HIGH−LOW−HIGH
level change at X5/28

3

Fly restart

Automatic start when
X5/28 = HIGH

l

Flying restart circuit is active

C0143 limit 2 kHz

0.0

0.0

{0.1 Hz}

20.0 Speed−dependent switching

threshold

l

Threshold for automatic
switching frequency reduction

l

The controller changes
automatically to 2 kHz when
this value falls below the
threshold

^
8.2−25

^
8.2−48

C0145

s

select ref

1

Selection of the flying restart
mode

l

Reference speed with which
the flying restart process is
started

^
8.2−36

^
8.2−65

0

REF: C0011

Maximum speed

1

REF: N−ACT

Last current speed

2

REF: N−SET

Defined main speed setpoint
It is referenced to the setpoint
signal at input NSET−N of the
function block NSET.
If the setpoint signal at input
NSET−N is missing, it is referenced
to the active JOG setpoint
(C0039/x)

C0146

fly current

0

−500

{1}

500 Flying restart circuit, quantity of

current during search process

l

Influences the current injection
during search process

l

±500

» ±39 % of I

max

l

The initial value amounts to

» 8 % of I

max

^
8.2−36

^
8.2−65

C0147 fly dt−f

0

−82

{1}

82 Flying restart circuit, search speed

during flying restart process

l

For drives with great
centrifugal masses, reduce the
search speed, if required

l

±82

¢ ±5.0 Hz

Advertising
This manual is related to the following products: