Configuration – Lenze EVF9333−xV User Manual

Page 264

Advertising
background image

Configuration

Function blocks
Diameter calculator (DCALC)

8

8.2
8.2.1

l

8.2−2

EDSVF9333V EN 6.2−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C1309

s

Dmin

50

1

{1 mm}

10000 Minimum diameter, function

block DCALC1

^
8.2−1

C1310 DCALC1−Titime

0.000 0.000

{0.001 s}

999.900 Acceleration and deceleration

time, function block DCALC1

C1311 window D−calc

1.00

0.00

{0.01 %}

100.00 Window − diameter calculation,

function block DCALC1

l

Window setting for permissible
diameter deviation

C1320

s

CFG: SET

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block DCALC1

l

The signal is scaled to the value
in C1304
(100 %

¢ C1304)

^
8.2−1

C1321

s

^ Selection list 2

Configuration of digital input
signals, function block DCALC1

1

CFG: LOAD

1000 FIXED0

l

HIGH: initial value at
DCALC1−SET is accepted

l

DCALC1−LOAD has a higher
priority than DCALC1−HOLD

2

CFG: HOLD

1000 FIXED0

l

HIGH = holds the diameter
value reached and resets the
integrators.

C1322

−36000

{1 rpm}

36000 Function block DCALC1

l

Display of the signals linked in
C1327

^
8.2−1

1 DIS: N−Line
2 DIS: N−WIND

C1325 DIS: SET

−199,99

{0.01 %}

199,99 Function block DCALC1

l

Display of the signal linked in
C1320

C1326

0

1 Function block DCALC1

l

Display of the signals linked in
C1321

1 DIS: LOAD
2 DIS: HOLD

C1327

s

^ Selection list 3

Configuration of input signals,
function block DCALC1

^
8.2−1

1 CFG: N−Line

1000 FIXED0INC

l

Speed signal of the line drive

2 CFG: N−WIND

1000 FIXED0INC

l

Speed signal of the winding
drive

C1328 DIS: D−ACT

−200

{1 mm}

200 Function block DCALC1

l

Display of the current diameter

The signal at DCALC1−Set is set as initial value.

ƒ With DCALC1−LOAD = 1 the initial value is accepted.

ƒ The initial value is accepted unfiltered.

Setting the initial value