8 heatsink temperature, Heatsink temperature, Configuration – Lenze EVF9333−xV User Manual

Page 345: Monitoring heatsink temperature

Advertising
background image

Configuration

Monitoring

Heatsink temperature

8

8.3

8.3.8

l

8.3−7

EDSVF9333V EN 6.2−04/2012

Diagram for the determination of the release times of a motor with a
thermal motor time factor of 5 min:

I

= 3 × I

mot

r

0

50

100

120

0

100

200

300

400

500

600

700

800

900

1000

t [s]

I t [%]

2

I

= 2 × I

mot

r

I

= 1.5 × I

mot

r

I

= 1 × I

mot

r

9300std105

Fig. 8.3−2

I

2

× t−monitoring: Release times for different motor currents and trigger

thresholds

Imot

Motor current

I

r

Rated motor current

I

2

t

I

2

t load

T

Time

8.3.8

Heatsink temperature

Via a temperature threshold, the heatsink temperature of the controller can
be monitored:

ƒ Adjustable threshold (OH4) under C0122

– The reset point is 5° C below the adjusted threshold.

ƒ Fixed threshold (OH) = 85° C

– The reset point is at 80° C.

The response for exceeding the adjustable threshold can be set under C0582.