Configuration

Code table

8

8.5

l

8.5−61

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0960 Function

1

Function selection, function block
CURVE1

See System
Manual
(extension)

1

Function 1

Characteristic with two base
points

2

Function 2

Characteristic with three base
points

3

Function 3

Characteristic with four base
points

C0961 y0

0.00

0.00

{0.01 %}

199.99 Configuration of base point y0,

function block CURVE1

l

Ordinate of the value pair
(x = 0 % / y0)

See System
Manual
(extension)

C0962 y1

50.00 0.00

{0.01 %}

199.99 Configuration of base point y1,

function block CURVE1

l

Ordinate of the value pair (x1 /
y1)

C0963 y2

75.00 0.00

{0.01 %}

199.99 Configuration of base point y2,

function block CURVE1

l

Ordinate of the value pair (x2 /
y2)

C0964 y100

100.0 0.00

{0.01 %}

199.99 Configuration of base point y100,

function block CURVE1

l

Ordinate of the value pair
(x 100 % / y100)

C0965 x1

50.00 0.01

{0.01 %}

99.99 Configuration of base point x1,

function block CURVE1

l

Abscissa of the pair (x1 / y1)

C0966 x2

75.00 0.01

{0.01 %}

99.99 Configuration of base point x2,

function block CURVE1

l

Abscissa of the pair (x2 / y2)

C0967

s

CFG: IN

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block CURVE1

See System
Manual
(extension)

C0968 DIS: IN

−199.99

{0.01 %}

199.99 Function block CURVE1

l

Display of the signal linked in
C0967

Advertising