Configuration, Code table – Lenze EVF9333−xV User Manual

Page 372

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−24

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0352 CAN mst

0

0

Slave

Configuration of the system bus
nodes

l

Change is effective after ˜Reset
node˜ command

1

Master

C0353

0

C0350 is the source

Source of the system bus address

1

C0354 is the source

1 CAN addr sel1

0

CAN IN1, CAN−OUT1

2 CAN addr sel2

0

CAN IN2, CAN−OUT2

3 CAN addr sel3

0

CAN IN3, CAN−OUT3

C0354

1

{1}

512 Selective system bus address

l

Individual addressing of the
system bus process data
objects

1 IN1 addr 2

129

CAN−IN1

2 OUT1 addr 2

1

CAN−OUT2

3 IN2 addr 2

257

CAN−IN2

4 OUT2 addr 2

258

CAN−OUT2

5 IN3 addr 2

385

CAN−IN3

6 OUT3 addr 2

386

CAN−OUT3

C0355

0

{1}

2047 System bus identifier

l

Read only

1 CAN−IN1 Id
2 CAN−OUT1 Id
3 CAN−IN2 Id
4 CAN−OUT2 Id
5 CAN−IN3 Id
6 CAN−OUT3 Id

C0356

0

{1 ms}

65000 System bus time settings

1 CAN boot−up

3000

Required for CAN interconnection
without master

2 OUT2 cycle

0

0 = event−controlled process data
transfer
>0 = cyclic process data transfer

3 OUT3 cycle

0

4 CAN delay

20

When the NMT state
"Operational" (after
"Pre−operational" or "Stopped")
has been reached, the delay time
˜CANdelay˜ is started. After the
delay time has e;apsed, the PDO´s
CAN−OUT2 and CAN−OUT3 are
sent for the first time.

C0357

0

{1 ms}

65000 System bus monitoring times

l

After a fault message, the CAN
objects remain in receive mode

1 CE1monit time

3000

CAN−IN1

2 CE2monit time

3000

CAN−IN2

3 CE3monit time

3000

CAN−IN3

C0358 Reset node

0

0

No function

Set the nodal reset pointof the
system bus

1

CAN reset

C0359 CAN state

0

Operational

System bus status

l

Read only

1

Pre−operational

2

Warning

3

Bus off

Advertising