Code table

8

8.5

l

8.5−34

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0536

−32767

{1}

32767 Function block DFSET

l

Display of the signals linked in
C0521, C0522 and C0523

^
8.2−18

1 DIS: VP−DIV
2 DIS: RAT−DIV
3 DIS: A−TRIM

C0537 DIS: N−TRIM

−199.99

{0.01 %}

199.99 Function block DFSET

l

Display of the signal linked in
C0524

C0538

0

1 Function block DFSET

l

Display of the signals linked in
C0525, C0526 and C0527

1 DIS: 0−pulse
2 DIS: RESET
3 DIS: SET

C0539 DIS: IN

−6000

{1 rpm}

6000 Function block DFSET

l

Display of the signal linked in
C0520

C0540

s

Function

0

Function selection, function block
DFOUT

l

Output signal at X10

^ 8.2−8

0

Analog input

Analog input

Signal at DFOUT−AN−IN is output.
Zero track can be input externally.

1

PH diff input

Phase difference
input

Signal at DFOUT−DF−IN is output.
Zero track can be input externally.

2

Not assigned

3

Not assigned

4

X10 = X9

X9 is output on
X10

The input signals are buffered
C0030 is without function

5

X10 = X8

X8 is output on
X10

C0541

s

CFG: AN−IN

5001 MCTRL−NACT

^ Selection list 1

Configuration of analog input
signal, function block DFOUT

l

Signal in [%] of C0011

C0542

s

CFG: DF−IN

1000 FIXEDPHI−0

^ Selection list 4

Configuration of input signal,
function block DFOUT

l

Speed signal

C0544

s

CFG: SYN−RDY

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block DFOUT

l

DFOUT−SYN−RDY = HIGH:
Generating a zero pulse

C0545 PH offset

0

0

{1 inc.}

65535 Phase offset, function block

DFOUT

l

Displacing the zero pulse
generated via DFOUT−SYN−RDY
by up to 360 °

l

1 rev. = 65535 inc (360 °)

C0546 Min inc/rev

1000 1

{1 inc.}

2147483647 Masking of the touch probe signal,

function block DFSET

l

Suppressing interference
pulses at X5/E4 (actual pulse of
touch probe signal)

l

The size of the masking
window between two actual
pulses is set

^
8.2−18