Commissioning

Changing the assignment of the control terminals X5 and X6
Free configuration of digital input signals

6

6.5
6.5.1

l

6.5−2

EDSVF9333V EN 6.2−04/2012

The internal digital signal can be linked with an external signal source by
entering the selection figure of the external signal into the configuration
code of the internal digital signal.

Example

ƒ C0787/2 =53

ð signal source for JOG2 is terminal X5/E3

E1

E2

E3

E4

E5

1

0

C0114/1...6

DIGIN

DIGIN1
DIGIN2

DIGIN3

DIGIN4
DIGIN5

28

DCTRL -X5/28

X5

DIGIN-CINH

1

1

ST

DIGIN6

C0443

NSET

C0046

NSET-N

DMUX

0

3

0

15

NSET-JOG*1
NSET-JOG *2
NSET-JOG *4
NSET-JOG *8

JOG1...15

C0780

C0787/1

C0787/2
C0787/3
C0787/4

9300vec105

Fig. 6.5−1

Connecting digital signal JOG2 with terminal X5/E3

I

Tip!

ƒ

A list with all selection figures is included in the chapter
"Configuration"

® "Selection lists".

ƒ

For signal linkage we recommend the function block editor in
GDC (ESP−GDC2).

ƒ Terminals (X5/E1 ... X5/E5):

– HIGH = +12 V ... +30 V
– LOW = 0 V ... +3 V

ƒ Response times: 1 ms

In C0114 you can define the active signal level (HIGH level active or LOW level
active) for the terminals X5/E1 ... X5/E5.

Example

ƒ C0114/3 =1

ð LOW level at X5/E3 activates JOG2

Linking signals

Signal level

Inverting the signal level