Configuration, Code table – Lenze EVF9333−xV User Manual

Page 390

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−42

EDSVF9333V EN 4.0−11/2007

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0690 Function

1

1

IN1 = IN 2

Function selection, function block
CMP3

l

Compare input signals at
CMP3−IN1 and CMP3−IN2

See System
Manual
(extension)

2

IN1 > IN2

3

IN1 < IN2

4

|IN1IN2|

5

|IN1IN2|

6

|IN1| < |IN2|

C0691 Hysteresis

1.00

0.00

{0.01 %}

100.00 Hysteresis, function block CMP3

l

Hysteresis for input signals
which are not stable and hence
the output oscillates

C0692 Window

1.00

0.00

{0.01 %}

100.00 Window, function block CMP3

l

Set the range in which the
signal comparison is to be
apply

C0693

s

^ Selection list 1

Configuration of analog input
signal, function block CMP3

1 CFG: IN

1000 FIXED0%

CMP3−IN1

2 CFG: IN

1000 FIXED0%

CMP3−IN2

C0694

−199.99

{0.01 %}

199.99 Function block CMP3

l

Display of the signals linked in
C0693

1 DIS: IN

CMP3−IN1

2 DIS: IN

CMP3−IN2

C0700

s

CFG: IN

19523 FCODE−472/3

^ Selection list 1

Configuration of analog input
signal, function block ANEG1

l

The value at ANEG1−IN is
multiplied by −1 and output

See System
Manual
(extension)

C0701 DIS: IN

−199.99

{0.01 %}

199.99 Function block ANEG1

l

Display of the signal linked in
C0700

C0703

s

CFG: IN

19523 FCODE−472/3

^ Selection list 1

Configuration of analog input
signal, function block ANEG2

l

The value at ANEG2−IN is
multiplied by −1 and output

See System
Manual
(extension)

C0704 DIS: IN

−199.99

{0.01 %}

199.99 Function block ANEG2

l

Display of the signal linked in
C0703